FKN12 / FKRN12 Indoor Load Break Switch

Select an indoor load break switch for a 12 kV, 50 Hz circuit, or specify the FKRN12 fuse-combination variant when the circuit needs coordinated fuse protection. The variant, fuse selection and operating mechanism determine the final switching duties.

FKN12 / FKRN12 SERIES SWITCH AND SWITCH-FUSE VARIANTS

FKN12 / FKRN12 Indoor Load Break Switch

Select an indoor load break switch for a 12 kV, 50 Hz circuit, or specify the FKRN12 fuse-combination variant when the circuit needs coordinated fuse protection. The variant, fuse selection and operating mechanism determine the final switching duties.

Rated voltage
12 kV
Rated frequency
50 Hz
Application
Indoor switching
Variants
Switch / switch-fuse
OVERVIEW

Load switching with an optional fuse combination

FKN12 is selected for the required indoor load-switching duty. The FKRN12 variant combines the switch with fuses whose rating, characteristic and striker interface form part of the protection arrangement. Specify the operating mechanism, earthing option and auxiliary contacts with the panel design. The approved variant and component schedule define the switching and protection duties.

Model designation

R identifies fuse protection. The applicable breaking duty depends on the switch variant and fuse combination.

F
Load break switch
K
Air medium
(R)
Fuse protection
N
Indoor
12
Design number
12
Rated voltage (kV)
D
Earthing switch
T
Spring mechanism
□
Rated current
□
Rated short-circuit breaking current (kA)
TECHNICAL DATA

FKN12 / FKRN12 technical specifications.

Electrical ratings

FKN12 / FKRN12 electrical ratings
Electrical parameterSpecification
Model optionsFKN12-12 switch family; FKRN12-12D fuse-combination family
Rated voltage12 kV
Rated frequency50 Hz
Active-load breaking current, switch variant630 A
Closed-loop breaking current, switch variant630 A
Cable-charging breaking current, switch variant10 A
Short-time withstand, switch variant20 kA for 4 s
Fuse-combination short-circuit breaking reference31.5 kA; confirm the selected fuse and complete combination
Continuous rated current and insulation scheduleObtain the confirmed variant-specific schedule before selection

Confirm the selected assembly, component ratings and verification documents. Family options do not describe every supplied configuration.

Configuration options

Match the equipment configuration to the circuit duty and installation interfaces.

FKN12 / FKRN12 functional-unit options
Selection itemSpecification / requirement
FKN12 load-switch variantSelect for the specified load-switching duty
FKRN12 fuse-combination variantConfirm fuse type, rating, striker and protection coordination
Earthing arrangementConfirm the ordered earthing-switch option and interlocks
Operating mechanismDefine manual or other specified operation, shaft and handle interfaces
Auxiliary contactsDefine required status signals and secondary wiring

Confirm the selected order code and component schedule before approval.

Protection & operation

Switching duties

Use the selected device only within its confirmed load-switching duties. Do not treat the switch variant as a general fault-interrupting circuit breaker.

Fuse coordination

For the combination variant, verify the fuse characteristic, transformer or load duty and transfer-current requirements together.

Earthing and access

Specify the selected earthing arrangement and interlocking sequence with the panel design.

Mechanism interface

Confirm operating direction, travel, linkage and auxiliary indication before integration.

Functional overview only. Qualified personnel must follow the approved isolation procedures and supplied operating instructions.

Define the equipment configuration.

Define the equipment duty and interfaces before requesting the project configuration.

FKN12 / FKRN12 configuration requirements
Configuration itemPurposeDefine for your project
Switch variantPerform the specified load-switching dutiesLoad type, switching current and frequency
Fuse-combination variantProvide coordinated fuse protectionFuse code, transformer or load data and fault study
Earthing and interlocksControl the approved access sequenceEarthing option and panel scheme
MechanismMatch the panel operating arrangementHandle, shaft, travel and auxiliary contacts
Engineering recordsConfirm integration requirementsVariant data sheet and approved drawings

Final components and scope of supply are defined in the project quotation.

Dimensions & interfaces

FKN12 / FKRN12 cabinet dimensions
InterfaceReference / requirementSelection note
Panel mountingRequest the selected mounting-hole and support drawingMatch cabinet space and clearances
Primary terminalsConfirm phase spacing and terminal geometryProvide conductor or bus arrangement
Operating linkageConfirm shaft, handle position and travelMatch panel door and operating access
Fuse accessAllow the selected fuse arrangement to be servicedConfirm replacement and isolation procedure
InterlocksDefine device-to-door and earthing interfacesApprove the panel scheme

Use the approved project drawing for dimensions, clearances, foundations and connections.

Installation

Panel integration

Check mounting, phase clearances, terminals, mechanism travel and servicing access against the selected drawing.

Circuit information

Provide the system voltage, frequency, load type, continuous current and available fault level.

Secondary circuits

Confirm any auxiliary contacts, control voltage and connection diagram for the ordered version.

Verification documents

Request the current variant-specific data sheet, arrangement drawing and applicable test evidence.

Site conditions

FKN12 / FKRN12 site conditions
ConditionRequirement / project input
LocationIndoor installation
Network12 kV, 50 Hz selection basis
EnvironmentState temperature, altitude, humidity and contamination
Mechanical installationProvide panel geometry and operating access
Nonstandard dutyConfirm capacitive, transformer or other special switching duties

Provide any conditions outside the stated range before ordering. Final suitability requires project-specific confirmation.

APPLICATIONS

Where FKN12 / FKRN12 is used

Indoor load-switching panels

Select the switching duty and coordinate the mechanism, contacts and earthing arrangement with the panel.

Transformer feeder protection

For an FKRN12 combination, check the selected fuse characteristics, load duty and transfer-current requirements together.

PLANNING EXAMPLE

Specifying a switch-fuse transformer feeder

Planning example: a transformer feeder calls for an FKRN12 switch-fuse combination. The switch, fuse and operating mechanism are selected together.

Define the circuit

Provide voltage, load current, transformer duty and the available fault level.

Coordinate the fuse

Confirm the fuse rating, time-current characteristic, striker interface and combination duties.

Approve panel interfaces

Check the mechanism travel, mounting, earthing option, indication and interlocking sequence.

MANUFACTURING & SUPPORT

Production, OEM and quality control

01 / PRODUCTION

Manufacturing

Production follows the approved drawings, the applicable product standards and the agreed inspection plan.

02 / CUSTOMIZATION

OEM & ODM

We can adjust the configuration for your operating environment and provide neutral packaging or your logo. Send the site conditions and branding requirements with your enquiry.

03 / QUALITY

Quality control

Incoming components, production work and finished units are checked against the requirements for the ordered configuration.

Inspection before dispatch

Material inspection

Incoming materials and components are checked against the approved specifications before production.

In-process checks

Assemblies and semi-finished components are inspected at the relevant production stages.

Final inspection

Finished equipment and release records are checked against the approved order requirements.

Factory acceptance testing (FAT). Every unit undergoes FAT before packing. Test items and acceptance criteria follow the product and approved configuration. FAT reports and packing inspection photos accompany the shipment. Factory attendance, video witnessing or independent inspection can be arranged with an agreed scope and schedule.

DOCUMENTS & ENQUIRY

Documents and quotation

Send your required ratings, installation conditions and quantity. We will confirm the configuration and documents for your quotation.

Selected FKN12 or FKRN12 assembly and rated duties.

Panel mounting, operating interface and earthing option.

Fuse coordination and applicable assembly verification.

Before you request a quote

FKN12 is the load-switch family. FKRN12 is the fuse-combination family; its protection duty depends on the selected fuse and complete combination.

Breaking duties and continuous current are separate ratings. Confirm continuous rated current for the selected order code.

Only select a device after checking the required switching and protection duties. The plain switch variant must not be treated as a general short-circuit breaking device.

Confirm the exact variant, earthing option and interlocking arrangement in the equipment schedule.

Send circuit voltage, load type, operating current, fault level, fuse requirements, panel drawing, operating mechanism and auxiliary-signal requirements.