GN19-12 Indoor Manual Disconnect Switch

Provide indoor isolation for a 12 kV circuit using a manually operated disconnect switch. GN19-12 is intended for switching without load current; select the current rating, mounting arrangement and CS6-1 operating mechanism interface for the panel.

GN19-12 SERIES NO-LOAD ISOLATION WITH MANUAL OPERATION

GN19-12 Indoor Manual Disconnect Switch

Provide indoor isolation for a 12 kV circuit using a manually operated disconnect switch. GN19-12 is intended for switching without load current; select the current rating, mounting arrangement and CS6-1 operating mechanism interface for the panel.

Rated voltage
12 kV
Rated-current options
400 / 630 / 1000 / 1250 A
Rated frequency
50 Hz
Operation
Manual, no-load isolation
OVERVIEW

Manual isolation for indoor circuits

GN19-12 provides manual no-load isolation in an indoor circuit. Select the continuous current and mounting variant with the primary terminals and cabinet layout. The CS6-1 mechanism, shaft and linkage must suit the operating position. The panel interlocks and operating procedure must establish the required no-load condition before the switch is operated.

Model designation

C identifies the through-wall variant. The two adjacent blank fields follow the original catalogue notation.

G
Disconnect switch
N
Indoor
19
Design number
12
Rated voltage
(C)
Through-wall type
□
Rated current (A)
□
Rated short-time withstand current
TECHNICAL DATA

GN19-12 technical specifications.

Electrical ratings

GN19-12 electrical ratings
Electrical parameterSpecification
Model familyGN19-12
Rated voltage12 kV
Rated frequency50 Hz
Rated-current options400 / 630 / 1000 / 1250 A
One-minute withstand to earth42 kV
One-minute withstand across open gap48 kV
Impulse withstand to earth75 kV
Impulse withstand across open gap85 kV
Short-time and peak withstandSelect the matched schedule for the ordered current variant
Switching dutyNo-load isolation; not a load break or fault-interrupting device

Confirm the selected assembly, component ratings and verification documents. Family options do not describe every supplied configuration.

Configuration options

Match the equipment configuration to the circuit duty and installation interfaces.

GN19-12 functional-unit options
Selection itemSpecification / requirement
Current ratingSelect 400, 630, 1000 or 1250 A against the circuit duty
Mounting variantConfirm the standard or through-wall configuration
Manual mechanismMatch the CS6-1 operating mechanism and linkage
Terminal arrangementConfirm primary connection dimensions and conductor direction
InterlockingDefine isolation, breaker and access interlocks with the panel

Confirm the selected order code and component schedule before approval.

Protection & operation

No-load operation

Establish the required no-load condition before operating, using the approved electrical isolation procedure.

Manual mechanism

Match handle, shaft and linkage travel to the selected device and cabinet.

Interlocking

Coordinate with the upstream switching device and access sequence to prevent an unsuitable operation.

Position indication

Confirm the visible position, auxiliary contacts where required and panel labelling.

Functional overview only. Qualified personnel must follow the approved isolation procedures and supplied operating instructions.

Define the equipment configuration.

Define the equipment duty and interfaces before requesting the project configuration.

GN19-12 configuration requirements
Configuration itemPurposeDefine for your project
Main disconnectProvide the selected isolation functionVoltage, current and withstand duty
Manual mechanismOperate the selected deviceCS6-1 interface, shaft and handle location
Mounting variantFit the panel or through-wall arrangementSupport, phase spacing and insulation geometry
InterlocksCoordinate the isolation and access sequenceBreaker status, access rules and operating scheme
Connection packageMatch the primary conductorsBusbar dimensions, terminals and approved drawing

Final components and scope of supply are defined in the project quotation.

Dimensions & interfaces

GN19-12 cabinet dimensions
InterfaceReference / requirementSelection note
Standard arrangementRequest the selected GN19-12 outlineConfirm support spacing, phases and terminal positions
Through-wall arrangementRequest the exact through-wall variant drawingMatch wall opening, insulation and support
Operating shaftConfirm shaft position, handle direction and linkage travelProvide the panel arrangement
TerminalsConfirm the drawing for the selected current ratingMatch busbar dimensions and hole pattern
Open positionCheck blade travel and insulation spaceApprove the complete compartment layout

Use the approved project drawing for dimensions, clearances, foundations and connections.

Installation

Mechanical fit

Approve mounting holes, phase spacing, terminals, open-blade space and operating linkage.

Electrical selection

Provide system voltage, frequency, continuous current and short-circuit withstand requirements.

Variant identification

Specify standard or through-wall mounting and the exact current code.

Documentation

Request the selected outline, operating instructions, rating schedule and applicable verification records.

Site conditions

GN19-12 site conditions
ConditionRequirement / project input
LocationIndoor
Network12 kV, 50 Hz selection basis
EnvironmentState temperature, altitude, humidity and contamination
Switching conditionOperate only within the confirmed no-load duty
InstallationPanel clearances and mechanism travel must match the approved drawing

Provide any conditions outside the stated range before ordering. Final suitability requires project-specific confirmation.

APPLICATIONS

Where GN19-12 is used

Indoor isolation arrangements

Coordinate the disconnect switch with the main switching device, earthing scheme and panel access sequence.

Panel retrofit or replacement

Check standard or through-wall mounting, terminal positions and the existing manual mechanism before selecting a unit.

PLANNING EXAMPLE

Fitting a manual disconnect into a panel

Planning example: a panel design needs a GN19-12 disconnect with an accessible manual operating position and a defined isolation sequence.

Select rating and variant

Provide circuit current, fault-withstand requirements and the standard or through-wall mounting choice.

Set the mechanism layout

Locate the CS6-1 handle, shaft and linkage, and check travel against the selected switch drawing.

Approve interlocks and indication

Coordinate the main device, no-load operating condition, access sequence and any auxiliary contacts.

MANUFACTURING & SUPPORT

Production, OEM and quality control

01 / PRODUCTION

Manufacturing

Production follows the approved drawings, the applicable product standards and the agreed inspection plan.

02 / CUSTOMIZATION

OEM & ODM

We can adjust the configuration for your operating environment and provide neutral packaging or your logo. Send the site conditions and branding requirements with your enquiry.

03 / QUALITY

Quality control

Incoming components, production work and finished units are checked against the requirements for the ordered configuration.

Inspection before dispatch

Material inspection

Incoming materials and components are checked against the approved specifications before production.

In-process checks

Assemblies and semi-finished components are inspected at the relevant production stages.

Final inspection

Finished equipment and release records are checked against the approved order requirements.

Factory acceptance testing (FAT). Every unit undergoes FAT before packing. Test items and acceptance criteria follow the product and approved configuration. FAT reports and packing inspection photos accompany the shipment. Factory attendance, video witnessing or independent inspection can be arranged with an agreed scope and schedule.

FURTHER READING

Related articles

Explore related guides for product selection, specifications and project planning.

Check power paths, protection, controls and equipment interfaces.

Frequently asked questions

It is specified here for no-load isolation. Use a correctly rated load switch or circuit breaker for duties that require load or fault interruption.

This page covers the manual configuration and CS6-1 mechanism interface. A motor-operated requirement needs a separately confirmed product configuration.

Match the continuous current and the complete short-time/peak withstand schedule to the circuit and installation conditions.

A through-wall arrangement is shown in the product material. Confirm the exact variant, current rating and installation drawing before order.

Send voltage, frequency, current, fault-withstand requirements, mounting variant, panel drawing, manual mechanism location and required interlocks.