40.5 kV Motor-Operated Drop-Out Fuse

A 40.5 kV outdoor drop-out fuse with a motor-driven operating mechanism. The RRW35-40.5/200-16 combines a 200 A current rating with a listed 16 kA breaking rating. Select the fuse link, drive supply and mounting arrangement for the protected circuit.

Category:
40.5 KV OUTDOOR FUSE

40.5 kV Motor-Operated Drop-Out Fuse

A 40.5 kV, 200 A outdoor drop-out fuse with a motor-operated mechanism. Select a 12 V DC or 24 V DC drive and specify the controls for the installation.

Rated voltage
40.5 kV
Rated current
200 A
Listed breaking current
16 kA
Motor supply options
12 / 24 V DC
OVERVIEW

How the motor-operated fuse works

The fuse link provides circuit protection. The motor moves the operating mechanism using the selected DC supply. Local or remote controls and position feedback are specified with the controller and wiring.

Product structure

40.5 kV component reference; use the approved drawing for installation. Insulator profile, mounting and dimensions depend on the ordered configuration.

The structure diagram is a series reference; use the approved outline drawing for mounting and clearances.

COMPARISON

Traditional and motor-operated drop-out fuses

Both use a fuse link for protection. The motor-operated fuse adds an electric operating mechanism; the controls and feedback are specified for the order.

On smaller screens, scroll the table sideways to compare both options.

Typical conventional cutout compared with 40.5 kV motor-operated fuse
What to compareTypical conventional cutout40.5 kV motor-operated fuse
Fault protectionThe fuse link melts and interrupts overcurrent within its rated duty.Fuse-link protection remains. The motor does not replace fuse selection or protection coordination.
Routine operationOn-site handling with suitable operating equipment.Motor operation from a local or remote command, under the approved operating conditions.
Status feedbackVisible dropout indication, with on-site checks.Specify local/remote commands and any position feedback with the controller.
Power and controlsNo motor supply is needed for the basic fuse assembly.Select a 12 V DC or 24 V DC motor with compatible control equipment and wiring.
After the fuse operatesThe operated fuse link must be replaced before returning the circuit to service.Fuse-link replacement is still required. Motor operation does not reset a blown fuse or make it an automatic recloser.
Switching under loadDepends on the cutout design and approved load-break equipment.Must be confirmed for the selected device. A motor alone does not establish load-break capability.

A conventional cutout suits installations with on-site operation. Consider the motor-operated fuse when the circuit also needs an electric operating mechanism.

TECHNICAL DATA

40.5 kV motor-operated fuse specifications

Ratings & fuse protection

40.5 kV electrical ratings
Electrical parameterSpecification
Reference configuration40.5 kV / 200 A / 16 kA
Rated voltage40.5 kV
Rated current200 A
Listed breaking current16 kA; confirm applicable duty and test coverage
Reference minimum creepage distance1255 mm
Motor supply12 V DC or 24 V DC
Device arrangementOutdoor drop-out fuse with electric operating mechanism

Match the listed 16 kA breaking rating to the required interruption duty and fuse link. Request the applicable test documents for the selected configuration.

Protection and switching

Select the fuse link for the protected load and system fault conditions. Motor operation does not establish load-break capability or an automatic reclosing function. Use the approved replacement link. Follow the supplied isolation and inspection instructions before returning the circuit to service.

Motor & controls

40.5 kV motor and control selection
Selection itemSpecification / requirement
Fuse selectionSpecify link rating and protection coordination
Drive supplySelect 12 V DC or 24 V DC
Control arrangementConfirm local/remote control and feedback
AccessoriesDefine operating tool, brackets, connectors and controller
Insulation requirementsConfirm site pollution and selected insulation schedule

Select one motor voltage and compatible controls. Specify the control box, commands and feedback with the order.

Mounting & connections

40.5 kV mounting and connection interfaces
InterfaceReference / requirementSelection note
Mounting baseSelected arrangement drawing requiredSupport dimensions and fasteners
Fuse movementMaintain operating clearanceAllow full opening movement
TerminalsConfirm conductor interfacesMaterial, cross-section and connector detail

Use the approved support, outline and terminal drawings for installation.

Before energization

Review the support drawing, phase arrangement, conductor loading and full operating movement. Check the fuse carrier, motor supply, control wiring and specified functions against the approved commissioning instructions.

Service conditions

40.5 kV service conditions
ConditionRequirement / project input
InstallationOutdoor
Reference ambient-30 to +45 C
Reference altitude1000 m
Reference ice thickness2 mm
Special exposureConfirm pollution, corrosion, wind and installation conditions

State any pollution, corrosion, wind or other site conditions beyond the reference schedule before ordering.

Applications

Outdoor fused circuits

Review the 40.5 kV voltage rating, 200 A current rating and fuse-link duty against the circuit and protected load.

Sites needing electric operation

Use the motor-operated mechanism with a selected DC supply. Specify the local/remote controls and feedback required at the site.

Existing installation replacement

Compare the mounting base, conductor interfaces, phase spacing and opening clearance with the proposed 40.5 kV fuse arrangement.

APPLICATION EXAMPLE

Motor operation for an outdoor fused circuit

Planning example for selecting a 40.5 kV motor-operated fuse assembly.

HJD catalog arrangement reference. This photograph does not document a 40.5 kV motor-operated fuse installation.

Operating requirement

A project needs fuse protection and an electric operating mechanism on an outdoor circuit.

Equipment and installation

Review the listed 40.5 kV, 200 A and 16 kA ratings against the circuit, fault current and fuse-link duty. Choose a 12 V DC or 24 V DC motor and compatible control equipment. Use the support and conductor drawings to check mounting, phase spacing and opening movement. Define the control-box location, wiring and acceptance checks before installation.

MANUFACTURING & SUPPORT

Production, OEM and quality control

01 / PRODUCTION

Manufacturing

Production follows the approved drawings, the applicable product standards and the agreed inspection plan.

02 / CUSTOMIZATION

OEM & ODM

We can adjust the configuration for your operating environment and provide neutral packaging or your logo. Send the site conditions and branding requirements with your enquiry.

03 / QUALITY

Quality control

Incoming components, production work and finished units are checked against the requirements for the ordered configuration.

Inspection before dispatch

Material inspection

Incoming materials and components are checked against the approved specifications before production.

In-process checks

Assemblies and semi-finished components are inspected at the relevant production stages.

Final inspection

Finished equipment and release records are checked against the approved order requirements.

Factory acceptance testing (FAT). Every unit undergoes FAT before packing. Test items and acceptance criteria follow the product and approved configuration. FAT reports and packing inspection photos accompany the shipment. Factory attendance, video witnessing or independent inspection can be arranged with an agreed scope and schedule.

DOCUMENTS & ENQUIRY

Request product documents or a quote

Send the system voltage, quantity, project location and control requirements. Add drawings or site photos if available.

Ratings, mounting dimensions and conductor interfaces.

Selected DC supply, control box, commands and feedback.

Model and duty covered by the available test documents.

Documents are selected for the proposed model and configuration.

Product questions

This is a separate 40.5 kV product rated at 200 A, with a listed 16 kA breaking-current rating. Use its own ratings, dimensions and operating documents.

The applicable interruption duty depends on the selected fuse link and configuration. Review the supporting test documents for the required duty.

This page defines the fuse assembly and motor supply options. Specify any monitoring or communications equipment separately.

No. Select the motor voltage and associated control equipment as one compatible configuration.

Send the system voltage, load and fault currents, quantity, motor supply, control requirements and site conditions. Add the support drawing if available.