12kV Load-Type Motor-Operated Drop-Out Fuse

A 12 kV motor-operated drop-out fuse with a dedicated arc-control device. Select the 100 A or 200 A version, porcelain or composite silicone-rubber insulation, and a 12 V DC or 24 V DC motor for the required switching duty.

Category:
12 KV LOAD-TYPE FUSE

12kV Load-Type Motor-Operated Drop-Out Fuse

A 12 kV motor-operated drop-out fuse with an arc-control device. Choose the 100 A or 200 A version, porcelain or composite insulation, and a 12 V DC or 24 V DC motor.

Rated voltage
12 kV
Rated current
100 / 200 A
Motor supply
12 / 24 V DC
Min. creepage
380 mm
OVERVIEW

The load-type fuse assembly

The fuse link provides overcurrent protection. A DC motor operates the mechanism, while a separate arc-control device forms part of the load-type construction.

Product structure

12 kV load-type component reference; not an installation drawing.

Identify the load-type structure

The load-type assembly includes an arc-control device at the upper contact area.

Load-switching duty is specified for the complete assembly. The listed 12.5 kA and 16 kA values are fuse breaking-current ratings.

COMPARISON

Standard and load-type motor-operated fuses

The catalog lists standard and load-type motorized versions. The load type adds an arc-control device.

On smaller screens, scroll the table sideways to compare both options.

Standard and load-type motorized fuses: construction and rating comparison
What to compareStandard motorized typeMotorized load type
Product designationElectric drop-out fuseElectric drop-out fuse, load type
Arc-control deviceNot shown on the standard-type drawingShown at the upper contact area
Rated voltage and current12 kV; 100 A / 200 A12 kV; 100 A / 200 A
Insulation and minimum creepagePorcelain or composite silicone rubber; 380 mmPorcelain or composite silicone rubber; 380 mm
Motor supply12 V DC / 24 V DC12 V DC / 24 V DC

The fuse breaking-current rating and the permitted load-switching duty are separate specifications. Use the operating instructions and test scope for the selected assembly.

TECHNICAL DATA

12 kV load-type fuse specifications

Fuse ratings & switching duty

12 kV electrical ratings
Electrical parameterSpecification
Product series12 kV load-type motor-operated drop-out fuse
Rated voltage12 kV
Rated current options100 A / 200 A
Listed fuse breaking-current ratings12.5 kA / 16 kA
Current / breaking-rating combinations100 A / 12.5 kA; 200 A / 16 kA
Insulation optionsPorcelain (C) / composite silicone rubber (H)
Minimum creepage distance380 mm
Load-switching dutyDefined for the selected assembly; the catalog does not list a separate numerical load-switching-current rating

Select the fuse link and coordinate it with the circuit protection. The model-code diagram pairs 100 A with 12.5 kA and 200 A with 16 kA.

Protection and operation

The arc-control device is part of the load-type design. Use the permitted switching duty and operating procedure for the ordered unit.

After the fuse operates, replace the specified fuse link and check the fault before restoring service. Select control commands and interlocks with the motor and controller.

Arc-control device components, shown as a construction reference.

Motor & operating controls

Select the electrical arrangement and interfaces for the intended duty.

12 kV motor and control selection
Selection itemSpecification / requirement
Motor voltage options12 V DC / 24 V DC
Fuse assembly12 kV, 100 A or 200 A, with C or H insulation
Operating controlsController and operating interface selected for the project
Fuse linksSpecify the required link and protection coordination
AccessoriesPower supply, wiring, mounting hardware and operating tools as ordered
System interfacesIntegration requirements specified separately

Select the controller, power supply and operating interface for the motor. Communication functions require their own agreed specification.

Mounting & connections

12 kV mounting and connection interfaces
InterfaceReference / requirementSelection note
Fuse assemblySelected outline drawing requiredUse the drawing for the ordered 12 kV version
Mounting baseConfirm support and hole patternCheck phase spacing and conductor loading
Arc-control device and movementAllow the full operating envelopeKeep installation clearances per the approved drawing
TerminalsConfirm conductor and connector interfacesSpecify conductor material, size and connection arrangement
Control equipmentConfirm position and cable routeCoordinate the selected DC supply and service access

Use the approved outline and terminal drawing for the selected 12 kV version.

Before energization

Check the support, terminals, arc-control device clearance and complete movement envelope. Verify the selected 12 V DC or 24 V DC supply, wiring, controls and operating sequence against the approved documents.

Service conditions

12 kV site conditions
ConditionRequirement / project input
InstallationOutdoor
Ambient temperature-30 to +45 C
AltitudeUp to 3,000 m
Radial ice thickness2 mm
Additional site inputsProvide pollution exposure, wind, corrosion conditions and installation requirements

Include pollution, wind and corrosion exposure with the site information. State any conditions outside these ranges.

Applications

12 kV distribution branches

Specify the required current and fuse protection for the branch, together with the permitted switching duty.

Replacing an existing cutout

Check the support, terminal positions and space for the added arc-control device against the existing installation.

Motor-operated distribution points

Select the 12 V DC or 24 V DC drive and the controller, power supply and operating interface used at the site.

APPLICATION EXAMPLE

Specifying a load-type fuse for a distribution branch

Selection example for project planning.

Operating requirement

The branch requires fuse protection and a motor-operated mechanism with a defined load-switching duty. Select the current version and fuse link for the circuit.

Equipment and installation

Match the DC supply and controls to the motor. Check the mounting points, terminals and arc-control device clearance, then review the permitted switching duty for the complete assembly.

MANUFACTURING & SUPPORT

Production, OEM and quality control

01 / PRODUCTION

Manufacturing

Production follows the approved drawings, the applicable product standards and the agreed inspection plan.

02 / CUSTOMIZATION

OEM & ODM

We can adjust the configuration for your operating environment and provide neutral packaging or your logo. Send the site conditions and branding requirements with your enquiry.

03 / QUALITY

Quality control

Incoming components, production work and finished units are checked against the requirements for the ordered configuration.

Inspection before dispatch

Material inspection

Incoming materials and components are checked against the approved specifications before production.

In-process checks

Assemblies and semi-finished components are inspected at the relevant production stages.

Final inspection

Finished equipment and release records are checked against the approved order requirements.

Factory acceptance testing (FAT). Every unit undergoes FAT before packing. Test items and acceptance criteria follow the product and approved configuration. FAT reports and packing inspection photos accompany the shipment. Factory attendance, video witnessing or independent inspection can be arranged with an agreed scope and schedule.

FURTHER READING

Related articles

Explore related guides for product selection, specifications and project planning.

Review components, ratings and fuse-link compatibility.

Frequently asked questions

The load-type motorized version includes an arc-control device. The standard motorized-type drawing does not show that device.

No. The catalogue lists them under breaking-current capacity for the fuse. It does not state a separate numerical load-switching-current rating. Confirm the required switching duty for the proposed device.

The fuse cutout ratings and switching guide separates fuse interruption from load-switching duty.

The model diagram shows 100 A with a 12.5 kA fuse breaking rating, and 200 A with a 16 kA rating. C denotes porcelain insulation and H denotes composite silicone rubber. Confirm the full model code for the ordered unit.

The motor options are 12 V DC and 24 V DC. Specify the controller, power supply and operating interface in the enquiry. No communication protocol, telemetry function or automatic-reclosing function is defined on this product catalogue page.

Send the project location, system voltage, required current, quantity, insulation preference and motor voltage. Identify the required switching duty and confirm the fuse links, controller, power supply, wiring, mounting hardware and document scope with the quotation.