SMSG Rectifier Phase-Shifting Transformer

A multi-winding phase-shifting transformer for the isolated supply of medium-voltage variable-frequency drive systems. Match the secondary-winding arrangement and phase shifts to the converter topology, then specify the electrical, cooling and mechanical interfaces as one coordinated design.

SMSG SERIES MULTI-WINDING DRIVE SUPPLY

SMSG Rectifier Phase-Shifting Transformer

A multi-winding phase-shifting transformer for the isolated supply of medium-voltage variable-frequency drive systems. Match the secondary-winding arrangement and phase shifts to the converter topology, then specify the electrical, cooling and mechanical interfaces as one coordinated design.

Listed capacity range
300-12000 kVA
Primary voltage options
3-10 kV family
Secondary arrangement
Multiple phase-shifted outputs
Cooling
Forced air
OVERVIEW

Coordinate the SMSG windings with the drive

SMSG provides multiple phase-shifted secondary outputs for the isolated supply of medium-voltage drive equipment. Winding count, phase relationships and loading must match the converter topology. Select the electrical schedule together with forced-air cooling, terminal identification and the installation envelope. Harmonic performance is assessed for the complete drive system.

TECHNICAL DATA

SMSG technical specifications.

Electrical ratings

SMSG electrical ratings
Electrical parameterSpecification
Product familySMSG rectifier phase-shifting transformer
ApplicationIsolated supply for high-voltage variable-frequency drive equipment
Load typeNon-sinusoidal converter load
Listed capacity range300-12000 kVA; confirm selected design
Primary voltage options3 / 3.3 / 4.16 / 6 / 6.3 / 6.6 / 10 kV
Reference secondary voltage630 V; other requirements need design confirmation
Secondary winding counts listed9 / 12 / 15 / 18 / 24
Tapping range listed+/-5%
Phase and frequencyThree-phase; 50 / 60 Hz
CoolingForced-air cooling
Thermal designConfirm insulation system and guaranteed temperature rise

Confirm the selected assembly, component ratings and verification documents. Family options do not describe every supplied configuration.

Winding & phase-shift options

The following angle groups are reference arrangements. The drive topology determines winding grouping, loading and terminal identification.

SMSG functional-unit options
Secondary winding countListed phase-shift anglesSelection requirement
9+20, 0, -20 degreesConfirm converter grouping and winding loads
12+22.5, +7.5, -7.5, -22.5 degreesConfirm full connection diagram
15+24, +12, 0, -12, -24 degreesConfirm full connection diagram
18+25, +15, +5, -5, -15, -25 degreesConfirm full connection diagram
24Project-specific arrangementObtain the approved angle schedule

Winding count alone does not define pulse number, harmonic performance or interchangeability with another drive.

Protection & operation

Converter matching

Provide the drive topology, winding loads and phase-shift requirements before transformer selection.

Harmonic duty

Account for the non-sinusoidal loading in the transformer specification. System harmonic performance requires the complete converter and network design.

Cooling and monitoring

Define fan supply, control, alarms and temperature monitoring for the chosen thermal design.

Protection coordination

Specify transformer and converter protection together with grounding and insulation requirements.

Functional overview only. Qualified personnel must follow the approved isolation procedures and supplied operating instructions.

Define the equipment configuration.

Define the equipment duty and interfaces before requesting the project configuration.

SMSG configuration requirements
Configuration itemPurposeDefine for your project
Drive supplyMatch converter inputsPrimary voltage, capacity and secondary-voltage schedule
Phase shiftingCoordinate winding groupsWinding count, angles, connections and individual loads
Thermal designSupport the duty cycleHarmonic loading, cooling and temperature monitoring
IntegrationFit the drive assemblyTerminals, enclosure space, airflow and protection interfaces

Final components and scope of supply are defined in the project quotation.

Dimensions & interfaces

SMSG cabinet dimensions
InterfaceReference / requirementSelection note
Transformer bodySelected general-arrangement drawingCapacity and winding arrangement determine size
Secondary terminalsTerminal and connection scheduleCoordinate every converter input and phase-shift group
Cooling systemFan and airflow arrangementDefine ventilation route and maintenance access
Drive integrationAvailable cabinet or room envelopeTransport, lifting, cables and service clearances

Reference dimensions support layout planning. Use the approved drawing for installation.

Installation

Interface approval

Approve the primary and secondary terminal schedule, winding identification and connection diagram with the drive integrator.

Airflow

Keep the designed cooling paths and access to fans clear; coordinate heat rejection with the enclosure or room.

Handling and access

Confirm transport dimensions, mass, lifting points and future service access on the selected drawing.

Acceptance

Agree the electrical checks, phase-shift verification and cooling/control checks for the delivered configuration.

Site conditions

SMSG site conditions
ConditionRequirement / project input
Operating environmentProvide site ambient, altitude, humidity and contamination
Load scheduleProvide converter topology, winding loads and duty cycle
Cooling supplySpecify fan supply and control requirements
Installation spaceConfirm enclosure or room ventilation and access
Performance requirementsAgree noise, losses, thermal and harmonic-related requirements

Provide any conditions outside the stated range before ordering. Final suitability requires project-specific confirmation.

APPLICATIONS

Where SMSG is used

New drive-system supplies

Define the converter topology, primary supply and individual secondary winding duties for the proposed drive.

Drive transformer replacement

Match the winding count, phase-shift schedule, terminal identification and loading to the existing converter.

Drive-system upgrades

Review changes in secondary demand, converter arrangement and cooling before specifying the replacement supply.

PLANNING EXAMPLE

supplying a medium-voltage drive

For a proposed SMSG transformer, the converter specification establishes the required secondary arrangement.

Map the converter outputs

Provide winding count, secondary voltages, phase-shift schedule and load on each winding.

Define electrical and thermal duty

Include primary voltage, frequency, capacity, harmonics, operating cycle and cooling requirements.

Coordinate installation

Confirm terminal labels, connections, airflow, protection interfaces and the available space.

MANUFACTURING & SUPPORT

Production, OEM and quality control

01 / PRODUCTION

Manufacturing

Production follows the approved drawings, the applicable product standards and the agreed inspection plan.

02 / CUSTOMIZATION

OEM & ODM

We can adjust the configuration for your operating environment and provide neutral packaging or your logo. Send the site conditions and branding requirements with your enquiry.

03 / QUALITY

Quality control

Incoming components, production work and finished units are checked against the requirements for the ordered configuration.

Inspection before dispatch

Material inspection

Incoming materials and components are checked against the approved specifications before production.

In-process checks

Assemblies and semi-finished components are inspected at the relevant production stages.

Final inspection

Finished equipment and release records are checked against the approved order requirements.

Factory acceptance testing (FAT). Every unit undergoes FAT before packing. Test items and acceptance criteria follow the product and approved configuration. FAT reports and packing inspection photos accompany the shipment. Factory attendance, video witnessing or independent inspection can be arranged with an agreed scope and schedule.

FURTHER READING

Related articles

Explore related guides for product selection, specifications and project planning.

Review their different roles in industrial power supplies.

Prepare electrical, installation, performance and acceptance requirements.

Frequently asked questions

No. SMSG is intended for multi-winding phase-shifted drive supply. The ZS page covers a separate medium-frequency furnace rectifier application.

The series is described for the isolated supply of high-voltage drive equipment. Compatibility still depends on the selected converter and winding design.

No. Harmonic performance depends on the complete drive and power system. A transformer family description is not a system test result.

Do not assume every listed option is interchangeable. Confirm the complete electrical and thermal design as a coordinated configuration.

Send the converter topology, capacity, primary voltage, secondary outputs, phase-shift schedule, winding loads, duty cycle, cooling requirements and installation envelope.